Subscreva a nossa newsletter para se manter atualizado
Clique aqui
  • BLS

What are the discomforts caused by the prolonged use of masks?

The importance of comfort in respiratory protective devices


 

Study conducted in collaboration with Integrated Therapies in Otolaryngology, Fondazione Policlinico Universitario Campus Bio-Medico.

Particle filtering facemasks (FFP) are the most commonly used personal protective equipment (PPE), particularly by healthcare workers. The purpose of a face mask is not only to protect the wearer from particles, droplets and aerosols, but also to prevent the spread of aerosol-borne viruses. There are 3 types of masks, according to their performance in filtering particles: FFP1 (> 80%), FFP2 (> 94%) and FFP3 (> 99%).

It is well known that healthcare workers have to wear these devices for many hours during their daily work activities and usually wear FFP2 face masks due to their high protection for both the user and others in the user's vicinity. However, very often face masks are perceived as uncomfortable and can cause difficulties in nasal breathing.

It has been observed that people who regularly use FFP2 or FFP3 masks may develop a new form of 'irritant rhinitis'. This is characterised by a strong inflammatory response in the nasal mucosa, with increased mast cell activation and IgE production, and a significant accumulation of polypropylene fibres (the main material composing the masks), resulting in worsening of nasal breathing and endoscopic rhinosinus findings.

Nasal obstruction can often cause difficulty in maintaining concentration and lead to a decline in work performance. Usually, these symptoms tend to disappear after three days without wearing the mask. However, wearing FFP face masks can be essential to protect ourselves and others.

 

BLS and the important collaboration with universities

BLS has always collaborated with a number of Italian universities to develop new and innovative projects, aware of the importance of collaboration between the academic and professional worlds. In recent years, in fact, BLS has carried out a study, in collaboration with the Campus Biomedico in Rome, on the discomfort caused by the prolonged use of masks.

Over a period of four months, healthcare workers at the Policlinico Universitario Campus Bio-Medico, including doctors and nurses, aged between 18 and 65, employed in operating theatres and outpatient activities, were asked to wear FFP2/N95 masks for the first seven days and FFP2/BLS 502 'high breathability' masks for the next seven days during their daily work activities. The study was approved by the Ethics Committee of the Fondazione Policlinico Universitario Campus Bio-Medico, as per the OS-FFP protocol.

At the end of the seven days of use of both masks, participants were assessed in terms of nasal cavity symptoms (oedema, irritation, secretion and crusting of the nasal mucosa), using a 3-point scale (0=none, 1=slight, 2=moderate, 3=severe). Each participant also completed a questionnaire on any discomfort experienced from the prolonged use of each mask (humidity, heat, respiratory resistance, itching, tightness, saltiness, feeling of inadequacy, odour, fatigue) and a questionnaire on nasal respiratory symptoms (nasal itching, nasal obstruction, rhinorrhoea, sneezing), using a visual analogue scale (1=none to 10=very much), reporting the data in a daily diary for the duration of each trial.

 

Results

When comparing the data from the two periods, better data were observed after seven days with the FFP2/BLS 502 mask compared to seven days with the FFP2/N95 mask, finding statistically significant differences for the following variables:

Results of the nasal cavity assessment in relation to the use of an FFP2/N95 mask (FFP2) compared to the use of an FFP2/BLS 502 mask (BLS 502) on a 3-point scale (0=none, 1=slight, 2=moderate and 3=severe).

Results of the questionnaire on discomfort in relation to the use of an FFP2/N95 (FFP2) mask compared to an FFP2/BLS 502 (BLS 502) mask on a scale of 0 (no discomfort) to 10 (maximum discomfort), represented as a mean.

Questionnaire results on nasal respiratory symptoms in relation to the use of an FFP2/N95 (FFP2) mask compared to the use of an FFP2/BLS 502 (BLS 502) mask on a scale of 0 to 10, represented as mean.

 

Furthermore, better results, although not statistically significant, were obtained for the BLS 502 mask in terms of sneezing and nasal itching.

 

 

The healthcare workers included in the study particularly appreciated the difference between the common FFP2 masks and the FFP2/BLS 502 masks in terms of breathability and reduced discomfort during work shifts.

 

 

Conclusions

Due to its design, which adapts to different face shapes and sizes, and its low breathing resistance, the FFP2/BLS 502 mask appears to be more comfortable to wear than a common FFP2/N95 mask. This is confirmed by the better results obtained in the nasal cavity assessment, the discomfort questionnaire and the nasal respiratory symptoms questionnaire.

 

 

Stay informed
Stay safe.

 

Artigos relacionados

maio 2, 2024 Donning instruction | BLS 2000 Series

Istruzioni d'indossamento | Serie BLS 2000 Indossare un DPI nel modo corretto è fondamentale per trarne massima efficacia e migliori performance di prodotto. La protezione respiratoria individuale ha lo scopo di difendere chi la utilizza da sostanze nocive o agenti patogeni presenti nell'aria. Prima di utilizzarla, è fondamentale ricevere un'adeguata formazione sul corretto metodo di […]

Link
novembro 18, 2021 Fit Test

Per Fit Test si fa riferimento ai metodi di valutazione dell'efficienza di un dispositivo di protezione respiratoria in termini di tenuta sul viso dell'utilizzatore. Perché eseguire un Fit Test? Sebbene negli ultimi anni si presti maggiore attenzione alla salute sui luoghi di lavoro, l'uso scorretto o l’inadeguata selezione dei dispositivi di protezione per le vie […]

Link
setembro 20, 2022 Safety Expo 2022

BLS è a Safety Expo 2022 Bergamo (Italia), 21-22 settembre 2022 L'evento di riferimento in Italia per la salute e la sicurezza dei luoghi di lavoro e la prevenzione incendi è tornato. Questa V edizione con i suoi 16000 MQ di esposizione è ricca di convegni, tavole rotonde, approfondimenti, corsi di formazione, spettacoli, prodotti, servizi e tecnologie.  Vieni a trovarci. Siamo allo stand […]

Link

Assine a newsletter

Receba atualizações sobre nossos eventos, notícias, catálogo e iniciativas futuras.
Inscreva-se

Contate-nos

Escreva-nos, responderemos em 48 horas.
Pedir informação

BLS S.R.L.
Società a Socio Unico
via dei Giovi, 41 - 20032 Cormano (MI) - Italia
t/f +39 02 39310212 / 66200473
info@blsgroup.it
Privacy Policy - Cookie Policy

Sede legal
via dei Giovi, 41 – 20032 Cormano (MI) - Italia
Capitale Sociale | Share Capital: Euro 600.000,00 i.v.
C.C.I.A.A. - R.E.A.: MI 1186898
Partita IVA | VAT N°: IT12296780153
C.F. e Iscrizione al Registro delle Imprese di Milano: 07822320151

BLS IBERIA / Av. Pau Casals, 8 08182 Sant Feliu de Codines Barcelona - Spain
BLS NORTHWEST / Reeweg, 132 3343 AP H.I. Ambacht Rotterdam - The Netherlands
BLS DO BRASIL / Rua Alvarenga Peixoto, 307 05095-010 Sao Paulo - SP - Brazil
BLS GERMANY / Steindeich 1a, 25377 Kollmar - Germany
BLS FRANCE / 18 Porte du Grand Lyon 01700 Neyron - France

crossmenuchevron-downcross-circle
PT