Focus | Serie BLS 4000next

Half-masks with b-lock bayonet connection


Today's product focus is on one of our best sellers.

Today's product focus is on one of our best sellers.
The reusable device for nose and mouth protection with b-lock connection, which can be disassembled and reassembled in less than 1 minute, facilitating cleaning and maintenance. It can be used in combination with protective glasses and it is available in two sizes and two materials. These half-masks are characterised by the high protection factor they provide when used in combination with b-lock bayonet connection filters (BLS 200 series) that protect against gases/vapours and toxic particulates.

Bayonet connection
Patented by BLS, this connection is highly intuitive, allowing a quick and safe hold on the mask. It has a locking feedback allowing the user to know if the filter has been properly placed. Moreover, the double filter offers better weight distribution on the mask and a greater field of vision during use.

Quick and easy maintenance
Thanks to its design, this half-mask can be disassembled and reassembled in less than 1 minute, making cleaning and maintenance much easier.

Drop-off system
A new front mask with quick attachment/release system and sliding elastics, which allow you to remove and lower the half mask without removing the head harness.

A lightweight face seal
Compared to masks of the past, the reduction in the thickness of the oronasal allowed a 25% reduction in the weight of the half mask, which appears to be among the lightest on the market.

Head harness
Thinner and lighter head harness, with a quick adjustment, allowing excellent compatibility with other PPE.

Ready-to-use kits
The silicone (BLS 4000next S) and thermoplastic rubber version (BLS 4000next R) of this product are also available in pre-assembled kits with various types of protection, depending on requiremen

BLS 4100next S kit with A2P2 NR protection
BLS 4400next S kit with ABEK1P3 R protection
BLS 4500next S kit with P3 R protection
BLS 4600next S kit with A2P3 R protection
BLS 4600next R kit with A2P2 NR protection

To discover more about

Access BLS 4000next product page to download the data sheets and find all the details you need.


 

Discover all BLS product compatibilities

This device is compatible with BLS 200 series filters with bayonet connection.

 

 

What's the color of your protection?

European standards EN 143 and EN 14387:2004+A1:2008 define protection against dust, gases and vapours on the basis of 10 types of contaminants which correspond to as many identification colours.

To safeguard against contaminants as gases and vapours, an active carbon filter is required, which is suitably treated to selectively adsorb the different substances. Activated carbon is characterised by its high porosity, which allows gases and vapours to be trapped on its internal surfaces, which are treated differently depending on the protection for one or more specific groups of substances. The table shows the different types of gases and vapours to be protected against, such as "A", "B", "E", "K", "AX", "Hg", "NO", "CO", "Reaktor".

 

 

And then there is protection from particulate matter, labelled "P", which is filtered by a pleated fabric that provides a larger filtering surface area and reduces respiratory fatigue.

 

Every protection has its own colur.

What is yours?

 

Why are some filters in this series not compatible with half masks?

BLS 200 series filters are bi-filters because they are designed to be worn in pairs on devices with this arrangement. When the total of both filters weighs more than 300g, wearing them on half-masks is not appropriate, because these devices only provide optimal comfort and tightness with filters weighing less.

Filters weighing more than 300g in this series are BLS 253 ABE2P3 R and BLS 254 ABEK2P3 R and are not compatible with half-masks.

 

Choose the protection that best suits your needs
Choose BLS

 

 

 

Le précédent
Virus

Articles Liés

février 8, 2022 Donning Instructions | BLS 510

Sai indossare correttamente un DPI? Indossare correttamente i DPI è importante per ottenere la massima efficacia e le migliori prestazioni di prodotto.   Lo scopo della protezione respiratoria individuale, infatti, è proteggere chi la indossa da sostanze tossiche o patogene diffuse per via aerea. Il suo utilizzo, quindi, dovrebbe essere preceduto da una formazione appropriata […]

Link
avril 16, 2024 Sawo 2024

BLS è a Sawo 2024 Poznań (Polonia), 23 - 25 aprile 2024 BLS è a Poznań alla fiera internazionale per la protezione del lavoro, antincendio e di salvataggio più grande per il settore SSL nell'Europa centrale e orientale. Vieni a trovarci. Siamo allo stand 24, padiglione 4.   La fiera L'evento, organizzato in un ciclo biennale, […]

Link
juillet 28, 2022 BLS ADV | 01

Never Stop Breathing | 01 Massimo Meregalli per BLS L'ADRENALINA INCONTRA LA SICUREZZA Massimo “Maio” Meregalli, direttore del Monster Energy Yamaha MotoGp team, è il primo soggetto scelto per la campagna Never Stop Breathing, che vuole essere un manifesto all'insegna della sicurezza attraverso le storie dei suoi protagonisti. Per saperne di più sul progetto e […]

Link

Abonnez-vous à la newsletter

Recevez des mises à jour sur nos événements, actualités, catalogue et initiatives à venir.
Souscrire

Nous contacter

Écrivez-nous pour tous vos besoins, nous vous répondrons dans les 48 heures.

Informations requises

Télécharger le guide de sécurité gratuit

Chaque secteur a besoin d'une protection adaptée. Pour en savoir plus, téléchargez notre guide de sécurité gratuit.
Scarica
crossmenuchevron-downcross-circle
FR