Suscríbase a nuestro boletín para estar al día
Haga clic aquí
  • BLS Products

Focus | BLS 2600next PAPR

BLS Powered Air Purifying Respirator with dust filter


What you need to overcome respiratory resistance

 

Powered breathing apparatuses use a battery-operated motor that draws air through filters to the full-face mask to which they are attached, supporting the user's breathing.

BLS 2600 next Powered Air Purifying Respirator (PAPR) is an assisted ventilation system for use with a full face mask and dust filter. It provides the user with filtered ambient air and thanks to the constant air flow and the absence of respiratory effort, is the ideal solution for heavy-duty use.

 

Suitable for long-term use

New rechargeable LI-Ion battery. High-performance and lightweight, the battery guarantees a battery life of over 10 hours for optimised comfort. When discharged, simply connect it to the robust and ergonomic connector until the LED on the charger signals.

 

Intuitive alarm management: what is it?

The innovative management system provides the operator with the following feedback via the 3 coloured LEDs: battery charge status, low battery alarm, flow blockage alarm, filter clogging alarm, charging status. All alarms are also signalled by sound and vibration. All alarms are also signalled by a sound and vibration. This multi-sensory feedback system (sound, visual, vibration) increases the level of user safety and comfort during use.

 

 

Experience automatic flow adjustment

Thanks to this system, a flow rate of 160 l/min is guaranteed, even if the filter is clogged.

 

What does the new IP66 certify?

The IP certification is an internationally recognised protection standard (IEC standard 60529) issued by International Protection. This certification identifies the resistance of any device to the intrusion of liquids, dust and solids.

Our PAPR was subjected to specific tests to test its resistance capabilities, based on which the protection code was determined.

The protection code is expressed in IPXX format, where the first number identifies the type of protection from dust and solid objects certified by the device, and the second number the protection from liquids. The BLS PAPR is certified as resistant to dust of any size and in the protection from waves or large jets of water (downpours, fountains, waves).

 

See all BLS product compatibilities

This device is compatible with BLS 5000 series full face masks with universal connection and silicone face seal (BLS 5400) or thermoplastic rubber (BLS 5150). The corrugated hose connection is inserted at the universal connection EN 148-1. This device is combined with the BLS TMP3 dust filter, which provides high filtration over long periods of time. This filter is protected by an easily removable ring nut and, thanks to a practical anti-water cap, is protected during the decontamination shower.

 

What is the decontamination shower?

At the end of use, it is essential to safely remove the PAPR and carry out the decontamination shower, to prevent the user from being contaminated by contaminants when removing the protective device. The DIN cap and filter cap will protect the motor and filter from water.Once this step is complete, simply follow the storage instructions and store all components in the sturdy storage box, which is equipped with four handles, a gasket and a padlock facility.

Go to BLS 2600next PAPR product page to download datasheets and find all the details you need.

 

Choose the protection best suited to your needs.
Choose BLS

 

 

 

Artículos relacionados

noviembre 9, 2021 BLS Webinar

Segui i nostri prossimi appuntamenti webinar! Di seguito il calendario con gli appuntamenti dei nuovi webinar, organizzati in collaborazione con EPC Editore, in cui tratteremo dei rischi che corrono le vie respiratorie in due specifici ambiti di lavoro.   Giovedì 11 novembre, ore 11.00-12.00 Rischi delle vie respiratorie in ambito verniciatura e dispositivi di protezione […]

Link
junio 23, 2022 2022-23 ADV Campaign teaser

Never Stop Breathing La qualità del vostro respiro è la base del nostro lavoro. Ecco perché ce ne prendiamo cura in ogni momento della vostra vita. Guarda questo video per scoprire il primo protagonista della nuova campagna ADV BLS, che ci accompagnerà per tutto il prossimo anno. Questo progetto di comunicazione nasce dai concetti sviluppati […]

Link
abril 11, 2024 Safety guide: healthcare sector

BLS Safety Guide: Settore sanitario Guida realizzata dalla monografia redatta dal Dott. Antonio Moffa, dalla Dott.ssa Claudia Beccaria e dall’Ing. Lucrezia Giorgi dell’Unità di Terapie Integrate in Otorinolaringoiatria della Fondazione Policlinico Universitario Campus Bio-Medico di Roma.   Il settore sanitario occupa circa il 10% dei lavoratori nell’Unione europea ed è pertanto uno dei più grandi […]

Link
Suscríbete al boletín
Reciba actualizaciones sobre nuestros eventos, noticias, catálogo y próximas iniciativas.
Suscribir

Contáctenos

Escríbanos para todas sus necesidades, le responderemos dentro de las 48 horas.
Información requerida

BLS S.R.L.
Società a Socio Unico
via dei Giovi, 41 - 20032 Cormano (MI) - Italia
t/f +39 02 39310212 / 66200473
info@blsgroup.it
Privacy Policy - Cookie Policy

Oficina registrada
via dei Giovi, 41 – 20032 Cormano (MI) - Italia
Capitale Sociale | Share Capital: Euro 600.000,00 i.v.
C.C.I.A.A. - R.E.A.: MI 1186898
Partita IVA | VAT N°: IT12296780153
C.F. e Iscrizione al Registro delle Imprese di Milano: 07822320151

BLS IBERIA / Av. Pau Casals, 8 08182 Sant Feliu de Codines Barcelona - Spain
BLS NORTHWEST / Reeweg, 132 3343 AP H.I. Ambacht Rotterdam - The Netherlands
BLS DO BRASIL / Rua Alvarenga Peixoto, 307 05095-010 Sao Paulo - SP - Brazil
BLS GERMANY / Dünner Straße 249 D-41066 Mönchengladbach - Germany
BLS FRANCE / 18 Porte du Grand Lyon 01700 Neyron - France

crossmenuchevron-downcross-circle